Dongguan Cableforce Electronics Co., Ltd

Dongguan Cableforce Electronics Co., Ltd

Home
Products
VR Show
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsM12 Circular Connector

Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding

Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding

  • Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding
  • Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding
Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding
Product Details:
Place of Origin: Guangdong, China
Brand Name: CABLEFORCE
Certification: UL Certified, CUL Certified, CE/ EMC, IP67, IP69K
Model Number: MC04P4LPDBP9
Payment & Shipping Terms:
Minimum Order Quantity: 100
Price: Negotiated
Packaging Details: Our standard packing: Individual part with transparent PE bag with label, OEM packing available.
Delivery Time: 2~3 weeks
Payment Terms: T/T
Supply Ability: 60000 pcs/month
Contact Now
Detailed Product Description
Contact Poles: 4 Pin Gender: Female
Temperature Rating: -40°C ~ + 105°C Current Rating: 4 A
Voltage Rating: 250 V Contacts Plating: 3μ" Gold Plating Thickness
Sealing: Epoxy Resin, O-Ring Panel Cut Size: PG9, M16x1.5
Insert: TPU Connector Flamability: UL94 V0
Compliance: RoHS Compliant, REACH Compliant Products Certification: UL Certified, CE/ EMC, IP67, IP69K
High Light:

d code m12 panel mount receptacle

,

4 pin m12 panel mount receptacle

,

female m12 panel mount receptacle

Profinet M12 D-Code 4Pin Female Panel Receptacle With PCB Contacts Rear Side Fastening With Ground Shielding
 
Connector Technical Data
Connector gender Female connector
Contacts termination PCB Dip Soldering
Coding
D coded
Contact material Phosphor bronze
Rated temperature -40℃~+80℃
Insert PA66+GF
Warranty 2-year quality guarantee period
Reference standard IEC 61076-2-101
Panel locking side Rear side fastening the nut
Housing/Outer shell Brass with nickel plasting
Insulation resistance
 
≥100mΩ
Contact resistance
 
≤5mΩ
EMC  
 
360°fully shielded 
 
Description of M12 D Code Female Panel Connector
 
The M12 metric size D-Coding connectors, it is commonly used connector in the Fieldbus cabling system, mainly designed and developed for industrial Ethernet/ Profinet cabling. M12 D-Coding connector designed with double keyway coding structure which differentiates itself from A, B, C, S, T, K, L-Codings.

● Cable plugs, field installable plugs, panel receptacles are available
● Cable length, LSZH, NFPA130 railway cable upon customer requesting
● Degree of protection IP67
● 4 poles per connector
● Operating voltage 250V; Current range: 4A
● 360° EMI-Shielded
● Anti-vibration locking screw design

 

We provide customers with the following cable custom services:

 

● Tailor made material to meet various application conditions
● Gold-plated solid brass or phosphor bronze contacts ≥ 600 times mating life
● Durable cable material suitable for Drag Chain moving and bending demands
● Good stripping and terminating properties
● Nylon plastic coupling screws with anti-vibration design

● UV Resistant, Hydrolysis Resistant,Oil resistant, Chemical resistant

 

● Temperature Range: Dynamic -25 ~ 80℃, Static: -40 ~ 80℃.

● Protection degree: IP67 in locked status, IP68 base on customer specific requirements.
● RoHS, REACH compliant.

 

FAQ

 

What is PROFIBUS and how it works?

Profibus (from process field bus) is a protocol for field bus communication in automation technology. Profibus links automation systems and controllers with decentralized field devices such as sensors, actuators, and encoders. Profibus networks exchange data using a single bus cable.

 

What does the coding mean on M12 connectors?

This coding prevents incorrect mating on products. In addition, shielding is available in most coded M12 connectors. For example, X-coded connectors are specifically shielded by the design of their coding.

 

What is difference between PROFIBUS and Ethernet?

PROFINET is a fieldbus system which is based on Ethernet. PROFINET is one of the many industrial ethernet systems out there, which is often compared to PROFIBUS. PROFINET is a full duplex system. Because it's ethernet based, PROFINET can operate on a much higher transmission speed than PROFIBUS.

 

 

Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding 0

Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding 1

https://www.m12cableconnector.com/

 

Profinet D Code 4 Pin Female M12 Panel Mount Receptacle With Pcb Contacts Rear Side Fastening With Ground Shielding 2

 

 

 

 

 

Contact Details
Dongguan Cableforce Electronics Co., Ltd

Contact Person: Marco Yang

Tel: 13509009528

Send your inquiry directly to us (0 / 3000)

Other Products